Vxel 威科赛尔

QC-01 / QUALITY STANDARD

Quality standard QC-01

We publish our own acceptance standard — items, methods, thresholds, sampling frequency. It is public, and you are welcome to hold us to it.

01 / WHY 12 ITEMS

Testing only B1 is enough to close an order, because the checklist asks for nothing else

The extra items bring no revenue — only cost. Vxel is in the brand-building stage with no large orders pressing on us: the manufacturer does not care what the brand is called, but someone building a brand has to. So every FEF-related item goes to the lab — including the ones nobody checks.

Once reports are issued, scans and report numbers are published on this page and can be verified with the issuing laboratory. Until then, everything below is a commitment to test, not a certification result. European standards EN 13501-1 / EN 14304 run on a second track — preparation under way, no conformity claim until those reports land (EN 14304 track →).

02 / TESTING LIST

Testing list (GB/T 17794 · GB 8624)

# Test item Standard Threshold Frequency Status
01 Thermal conductivity GB/T 17794 ≤ 0.034 W/(m·K) Per batch Testing
02 Reaction to fire class GB 8624 Class B1 Type + per batch Testing
03 Moisture resistance factor μ GB/T 17794 Pending verification Type Testing
04 Oxygen index GB/T 17794 Pending verification Type Testing
05 Smoke density GB/T 17794 Pending verification Type Testing
06 Vacuum water absorption GB/T 17794 Pending verification Per batch Testing
07 Density GB/T 17794 Pending verification Per batch Testing
08 Tensile strength GB/T 17794 Pending verification Type Testing
09 Dimensional stability GB/T 17794 Pending verification Type Testing
10 Water vapour permeability GB/T 17794 Pending verification Type Testing
11 Low-temperature resistance GB/T 17794 No cracking, no detachment Type Testing
12 High-temperature resistance GB/T 17794 No flow, no deformation Type Testing

Full-item testing under way Each report published with its number once issued, verifiable with the issuing lab

EN 13501-1 / EN 14304 Not yet submitted, no claim

Rows 03–10 show the acceptance thresholds the reports are judged against (demo figures); the issued report is the final word. We do not assert conformity with the European standards until they are submitted and reported.

03 / INSPECTION FLOW

Inspection flow

  1. 01 Batch-by-batch testing — Not once a year — every batch
  2. 02 Sample retention — Kept 12 months, fully traceable
  3. 03 Third-party re-check before dispatch — Appearance and specification checked together
  4. 04 Failed batches isolated in full — No downgrade, no blending, no dispatch
  5. 05 Reports ship with the goods — Traceable to the production date at sign-off
  6. 06 On-site inspection — Our staff on critical batches, with the authority to refuse delivery

“Failed batches isolated in full” is the hardest commitment on this page — it is what makes the rest of it enforceable.

04 / PAYMENT & SCHEDULING

Why the first order is paid up front

Because payment is what turns your order into a scheduled batch — not into someone else's credit line. That means: your peak-season slot is not moved; your payment stays with your batch; the price holds when supply tightens. Agents ask for credit because they need your money to fund their turnover. We do not take credit terms — so your order does not wait on someone else's payment.

05 / REPORT ARCHIVE

Report archive

Once issued, scan copies and report numbers are published here and can be verified with the issuing laboratory.

No reports issued yet Scan copies and report numbers appear here one by one as they are issued

Request the reports or spec sheets

Reports go out as soon as they are issued. WhatsApp and email are the primary routes; phone is the second choice overseas.