STANDARDS / EN 14304 TRACK
One product,
two sets of proof
GB/T 17794 and GB 8624 are the evidence Chinese projects ask for. European buyers ask for EN 14304 and EN 13501-1 — a different list, tested under different methods. We do not translate one into the other. We opened a second track.
A GB report does not become an EN report by translation
EN 14304 is the European product standard for factory-made FEF insulation; EN 13501-1 is its fire classification. The methods, the thresholds and the report format all differ from their GB counterparts. A European contractor cannot accept a GB 8624 B1 result as if it were a Euroclass — and we will not pretend otherwise.
The GB track is public and keeps running (QC-01, 12 items, batch by batch →). This page is the EN track — same discipline, second set of proof.
The item list, before it is a result
| NO. | Test item | Method | What it declares | Status |
|---|---|---|---|---|
| 01 | Thermal conductivity λ | EN 12667 | Declared λ at 10 °C mean temperature | Preparing |
| 02 | Reaction to fire class | EN 13501-1 · EN ISO 11925-2 / EN 13823 | Euroclass, incl. smoke (s) and flaming droplets (d) | Preparing |
| 03 | Water vapour diffusion resistance | EN 12086 | Moisture resistance factor μ | Preparing |
| 04 | Water absorption, short-term | EN 1609 | Partial immersion (WS) | Preparing |
| 05 | Dimensional stability | EN 1604 | Under temperature and humidity | Preparing |
| 06 | Tensile strength ⊥ to faces | EN 1607 | TR — bonding and handling quality | Preparing |
| 07 | Compression behaviour | EN 826 | CP — for loaded applications | Preparing |
| 08 | Thickness and tolerances | EN 823 | Declared thickness, tolerance class | Preparing |
| 09 | Density | EN 1602 | Declared density | Preparing |
| 10 | Durability of λ and μ | EN 14304 | Aging rationale, declared | Preparing |
This is a plan, not a result Thresholds get locked against the EN 14304 tables once the lab confirms scope
Nothing on this page is a conformity claim. Until reports are issued: no CE marking, no Declaration of Performance, no EN fire class claimed, translated or implied. When the reports land, scans and numbers are published here, verifiable with the issuing laboratory.
The GB track — QC-01 full list →Three things you will not see from us — yet
- 01
No CE marking
CE marking for FEF under the CPR becomes possible only after this track is complete and a Declaration of Performance is drawn up. Not before, not "coming soon".
- 02
No translated fire class
A GB 8624 B1 result is not a Euroclass. We will not label, imply or convert one into the other — ask us for each separately.
- 03
No "equivalent to EN 14304"
Equivalence is not a seller’s judgement to make. What we publish instead: the GB data and the EN track status, side by side.
When the EN report lands, it goes public on this page —
same rule as the GB track.
Where the track stands
- 01
Scope fixed with the lab
Items, methods and thresholds set against the EN 14304 tables — then this page shows them, item by item.
- 02
Samples dispatched
Samples taken from the same production batches as the GB track — not a prepared showcase sample.
- 03
Testing under EN methods
At an accredited laboratory. However long the methods take, this page keeps the honest status.
- 04
Published here
Scans and report numbers on this page, verifiable with the issuing lab — same rule as the GB track.
No dates until the lab confirms a schedule — we do not write deadlines we cannot show on a calendar.
Buying for an EU project?
Ask us where the EN track stands today — you get the honest status, not a promise. If your schedule cannot wait for the EN report, we will say so instead of letting you find out at customs.